Home Page    Bioenergy    Household Biogas Products    ISO certificate support house used diaphragm gas flow meter
4941750901e55ecf55504867b684610b_34445315
8157efc9780807e0c04d4be35c60d9c6_34445314
ae2d3674755aad6322701ca74af8e6a8_34445313

ISO certificate support house used diaphragm gas flow meter

AM-1 impeller type radio frequency card gas meter is the most advanced gas flow metering precision instrument, it is on TYG - AM-1 gas meter on the basis of the impeller type, combining with the rf circuit design and become, besidesAM-1 impeller type gas meter product structure characteristics, circuit adopts radio frequency card read/write mode, compared to traditional contact card .has incomparable advantage

The product features
Impeller type radio frequency card gas meter not only overcomes the defect of diaphragm gas meter.And electronics in the rf card circuit, all through the screening of high and low temperature environment test, circuit external spray-up moistureproof thermal conductive foam.Can protect the quality of the product and service life.
The range of application
Impeller type radio frequency card gas meter is suitable for the gas, and other various gas measurement.

Specifications

Maximum flow:Qmax(m3/h):1.6/2.5/4

Minimum flow Qmin(m3/h):0.016/0.025/0.04;

The maximum working pressure(Pa):0.5-20;

Recycling(dm3):1:2;

Basic error:0.1 Qmax≤Q≤Qmax:

± 1.5%

Qmax≤Q≤0.1Qmax:±3%;

Maximum pressure loss(pa):≤200;

Connector:130;

Joint rib:M30*2;

Max reading(m):9999.999;

Min reading(m):0.0002;

Weight:2kg

Packaging, storage, directions for use

1, solid gas meter should be loaded in the box, do not allow the gas meter in the free running in the cabinet, handle with care when handling.
2, gas meter should be stored in rain moisture, not affected by mechanical vibration or shock, temperature range - 10 ~ + 40, environment relative humidity of 80% or less.
3, gas meter installation should be appearance inspection, check the gas meter for damage in transit.
4, before installation should be sealed performance check, enter 1.5 times the maximum working pressure of compressed air, close the export checking for leakage phenomenon.It is forbidden to open fire.
5, gas meter shall be installed level, no tilt, inversion, does not apply to strong vibration, installation time is consistent with the direction of the gas and air flow direction.
6, without the consent of the department of management, the user may not arbitrarily disassembling or unsealed debugging, to ensure the accuracy of gas meter and the safety of the user.

Created on:2024-10-10 15:02
PV:0
Collect
Add to cart
Price:
¥ 0.00
Quantity:
Verification code